1. Inbuilt Military Standard BMS: It has a built-in Multi-functional 120A continuous BMS, 360A for 30 sec peak, with high-quality IC and MosFET for over-current, over-discharge, over-charge, short-circuit, adverse-polarity connection, balancing functions. 2. Wide Applications: It can be used for solar energy 1
LiFePO4 batteries for solar storage: Cycle stability at high current, Fast charging within 1 hour, Deep discharge protection, overcharge protection, Voltage and temperature monitoring, Single cell monitoring, State of charge determination(SOC and SOH).
Li-ion Marine Batteries 12V 48V 240Ah: Light weight and strong power, sell to France and Russia and gain best praise, customers show it on their website to expand markets.
Item NO.:
KOK-PS-01Brand:
KOK POWER
Multi-Functional Portable UPS lithium ion power station battery batteries 3.7v
General Introductions
Specifications |
500W |
Nominal voltage of the battery |
11.1V |
AC source |
|
Output voltage |
110V-235V±5V |
Output |
110V-235V/50Hz/60Hz±1% |
Output waveform |
Pure Sine Wave (sinusoidal) |
THD |
≤ 3% |
Rated output power |
500W |
Overload power |
550W(15S), Peak 1000W(5S) |
DC output |
|
USB output |
5V 2.1A |
DC output |
12V 5A |
System parameters |
|
Conversion efficiency |
≥88% |
AC source conversion time |
<6ms |
Accuracy of battery level |
±5% |
Static power |
≤0.4A |
Cooling fan |
When the system starts up, the cooling fan will run 10 seconds before it stops. It will start working between 45-50℃ and stop working when it is lower than 45℃ (circulation) |
Power failure |
green light: OK/red light: failure |
Charging indicator |
red light: being charged/green light: fully charged |
DC output power indicator |
green light: OK/red light: failure |
AC charging |
|
Input voltage |
110V-265V |
Charging voltage |
12.6V |
Charging current |
5A |
|
|
Solar charging |
|
Charging voltage |
12.6-26V |
Charging current |
5A |
|
|
Protection |
|
Under-voltage protection |
9V |
Overload protection |
100% overload: it will give alarms for 15 seconds before the system shuts down. 120% overload: it will give alarms for 10 seconds before the system shuts down. >120% overload: it will shut down immediately. |
Short-circuit protection |
The system will shut down immediately. When short-circuit is removed, the system will be restored automatically. |
Temperature protection |
55-65℃ |
Dimension |
|
Overall dimension (mm) |
T184*W131*L315 |
Power panel dimension (mm) |
T10*W120*L210 |
Environmental index |
|
Working temperature |
-10℃-55℃ |
Storage temperature |
0℃-30℃ |
Humidity |
20-90% |
Long time storage charging |
20-30 days |
prev :